Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 19.705
Filtrar
1.
BMC Oral Health ; 24(1): 455, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622680

RESUMO

BACKGROUND: The aim of this study is to evaluate the biomechanical behavior of the mesial and distal off-axial extensions of implant-retained prostheses in the posterior maxilla with different prosthetic materials using finite element analysis (FEA). METHODS: Three dimensional (3D) finite element models with three implant configurations and prosthetic designs (fixed-fixed, mesial cantilever, and distal cantilever) were designed and modelled depending upon cone beam computed tomography (CBCT) images of an intact maxilla of an anonymous patient. Implant prostheses with two materials; Monolithic zirconia (Zr) and polyetherketoneketone (PEKK) were also modeled .The 3D modeling software Mimics Innovation Suite (Mimics 14.0 / 3-matic 7.01; Materialise, Leuven, Belgium) was used. All the models were imported into the FE package Marc/Mentat (ver. 2015; MSC Software, Los Angeles, Calif). Then, individual models were subjected to separate axial loads of 300 N. Von mises stress values were computed for the prostheses, implants, and bone under axial loading. RESULTS: The highest von Mises stresses in implant (111.6 MPa) and bone (100.0 MPa) were recorded in distal cantilever model with PEKK material, while the lowest values in implant (48.9 MPa) and bone (19.6 MPa) were displayed in fixed fixed model with zirconia material. The distal cantilever model with zirconia material yielded the most elevated levels of von Mises stresses within the prosthesis (105 MPa), while the least stresses in prosthesis (35.4 MPa) were recorded in fixed fixed models with PEKK material. CONCLUSIONS: In the light of this study, the combination of fixed fixed implant prosthesis without cantilever using a rigid zirconia material exhibits better biomechanical behavior and stress distribution around bone and implants. As a prosthetic material, low elastic modulus PEKK transmitted more stress to implants and surrounding bone especially with distal cantilever.


Assuntos
Implantes Dentários , Zircônio , Humanos , Análise de Elementos Finitos , Maxila/cirurgia , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/métodos , Estresse Mecânico
2.
BMC Musculoskelet Disord ; 25(1): 285, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609902

RESUMO

OBJECTIVE: To investigate the effect of bone cement on the vertebral body and biomechanical properties in percutaneous cement discoplasty (PCD) for degenerative lumbar disc disease. METHODS: Three-dimensional reconstruction of L2 ~ L3 vertebral bodies was performed in a healthy volunteer, and the corresponding finite element model of the spine was established. Biomechanical analysis was performed on the changes in stress distribution in different groups of models by applying quantitative loads. RESULTS: Models with percutaneous discoplasty (PCD) showed improved stability under various stress conditions, and intervertebral foraminal heights were superior to models without discoplasty. CONCLUSION: Cement discoplasty can improve the stability of the vertebral body to a certain extent and restore a certain height of the intervertebral foramen, which has a good development prospect and potential.


Assuntos
Escoliose , Humanos , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Análise de Elementos Finitos , Cimentos Ósseos/uso terapêutico , Coluna Vertebral , Voluntários Saudáveis
3.
Med Eng Phys ; 126: 104136, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38621835

RESUMO

Computer representations of three-dimensional (3D) geometries are crucial for simulating systems and processes in engineering and science. In medicine, and more specifically, biomechanics and orthopaedics, obtaining and using 3D geometries is critical to many workflows. However, while many tools exist to obtain 3D geometries of organic structures, little has been done to make them usable for their intended medical purposes. Furthermore, many of the proposed tools are proprietary, limiting their use. This work introduces two novel algorithms based on Generalized Regression Neural Networks (GRNN) and 4 processes to perform mesh morphing and overclosure adjustment. These algorithms were implemented, and test cases were used to validate them against existing algorithms to demonstrate improved performance. The resulting algorithms demonstrate improvements to existing techniques based on Radial Basis Function (RBF) networks by converting to GRNN-based implementations. Implementations in MATLAB of these algorithms and the source code are publicly available at the following locations: https://github.com/thor-andreassen/femors; https://simtk.org/projects/femors-rbf; https://www.mathworks.com/matlabcentral/fileexchange/120353-finite-element-morphing-overclosure-reduction-and-slicing.


Assuntos
Algoritmos , Redes Neurais de Computação , Análise de Elementos Finitos , Software , Fenômenos Biomecânicos
4.
Med Eng Phys ; 126: 104130, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38621832

RESUMO

Biphasic models have been widely used to simulate the time-dependent biomechanical response of soft tissues. Modelling techniques of joints with biphasic weight-bearing soft tissues have been markedly improved over the last decade, enhancing our understanding of the function, degenerative mechanism and outcomes of interventions of joints. This paper reviews the recent advances, challenges and opportunities in computational models of joints with biphasic weight-bearing soft tissues. The review begins with an introduction of the function and degeneration of joints from a biomechanical aspect. Different constitutive models of articular cartilage, in particular biphasic materials, are illustrated in the context of the study of contact mechanics in joints. Approaches, advances and major findings of biphasic models of the hip and knee are presented, followed by a discussion of the challenges awaiting to be addressed, including the convergence issue, high computational cost and inadequate validation. Finally, opportunities and clinical insights in the areas of subject-specific modeling and tissue engineering are provided and discussed.


Assuntos
Cartilagem Articular , Modelos Biológicos , Humanos , Fenômenos Biomecânicos , Articulações/fisiologia , Cartilagem Articular/fisiologia , Simulação por Computador , Articulação do Joelho/fisiologia , Análise de Elementos Finitos
5.
J Biomech Eng ; 146(9)2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558117

RESUMO

State-of-the-art participant-specific finite element models require advanced medical imaging to quantify bone geometry and density distribution; access to and cost of imaging is prohibitive to the use of this approach. Statistical appearance models may enable estimation of participants' geometry and density in the absence of medical imaging. The purpose of this study was to: (1) quantify errors associated with predicting tibia-fibula geometry and density distribution from skin-mounted landmarks using a statistical appearance model and (2) quantify how those errors propagate to finite element-calculated bone strain. Participant-informed models of the tibia and fibula were generated for thirty participants from height and sex and from twelve skin-mounted landmarks using a statistical appearance model. Participant-specific running loads, calculated using gait data and a musculoskeletal model, were applied to participant-informed and CT-based models to predict bone strain using the finite element method. Participant-informed meshes illustrated median geometry and density distribution errors of 4.39-5.17 mm and 0.116-0.142 g/cm3, respectively, resulting in large errors in strain distribution (median RMSE = 476-492 µÎµ), peak strain (limits of agreement =±27-34%), and strained volume (limits of agreement =±104-202%). These findings indicate that neither skin-mounted landmark nor height and sex-based predictions could adequately approximate CT-derived participant-specific geometry, density distribution, or finite element-predicted bone strain and therefore should not be used for analyses comparing between groups or individuals.


Assuntos
Fíbula , Tíbia , Humanos , Tíbia/diagnóstico por imagem , Fíbula/diagnóstico por imagem , Análise de Elementos Finitos , Marcha , Modelos Estatísticos , Densidade Óssea
6.
Sci Rep ; 14(1): 7794, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565625

RESUMO

In this study, a commercial dental resin was reinforced by SiO2 nanoparticles (NPs) with different concentrations to enhance its mechanical functionality. The material characterization and finite element analysis (FEA) have been performed to evaluate the mechanical properties. Wedge indentation and 3-point bending tests were conducted to assess the mechanical behavior of the prepared nanocomposites. The results revealed that the optimal content of NPs was achieved at 1% SiO2, resulting in a 35% increase in the indentation reaction force. Therefore, the sample containing 1% SiO2 NPs was considered for further tests. The morphology of selected sample was examined using field emission scanning electron microscopy (FE-SEM), revealing the homogeneous dispersion of SiO2 NPs with minimal agglomeration. X-ray diffraction (XRD) was employed to investigate the crystalline structure of the selected sample, indicating no change in the dental resin state upon adding SiO2 NPs. In the second part of the study, a novel approach called iterative FEA, supported by the experiment wedge indentation test, was used to determine the mechanical properties of the 1% SiO2-dental resin. Subsequently, the accurately determined material properties were assigned to a dental crown model to virtually investigate its behavior under oblique loading. The virtual test results demonstrated that most microcracks initiated from the top of the crown and extended through its thickness.


Assuntos
Nanopartículas , Dióxido de Silício , Dióxido de Silício/química , Resinas Compostas/química , Análise de Elementos Finitos , Nanopartículas/química , Fenômenos Mecânicos , Teste de Materiais
7.
J Orthop Surg Res ; 19(1): 209, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561837

RESUMO

BACKGROUND: Previous studies have demonstrated the clinical efficacy of decompression alone in lower-grade spondylolisthesis. A higher rate of surgical revision and a lower rate of back pain relief was also observed. However, there is a lack of relevant biomechanical evidence after decompression alone for lower-grade spondylolisthesis. PURPOSE: Evaluating the biomechanical characteristics of total laminectomy, hemilaminectomy, and facetectomy for lower-grade spondylolisthesis by analyzing the range of motion (ROM), intradiscal pressure (IDP), annulus fibrosus stress (AFS), facet joints contact force (FJCF), and isthmus stress (IS). METHODS: Firstly, we utilized finite element tools to develop a normal lumbar model and subsequently constructed a spondylolisthesis model based on the normal model. We then performed total laminectomy, hemilaminectomy, and one-third facetectomy in the normal model and spondylolisthesis model, respectively. Finally, we analyzed parameters, such as ROM, IDP, AFS, FJCF, and IS, for all the models under the same concentrate force and moment. RESULTS: The intact spondylolisthesis model showed a significant increase in the relative parameters, including ROM, AFS, FJCF, and IS, compared to the intact normal lumbar model. Hemilaminectomy and one-third facetectomy in both spondylolisthesis and normal lumbar models did not result in an obvious change in ROM, IDP, AFS, FJCF, and IS compared to the pre-operative state. Moreover, there was no significant difference in the degree of parameter changes between the spondylolisthesis and normal lumbar models after undergoing the same surgical procedures. However, total laminectomy significantly increased ROM, AFS, and IS and decreased the FJCF in both normal lumbar models and spondylolisthesis models. CONCLUSION: Hemilaminectomy and one-third facetectomy did not have a significant impact on the segment stability of lower-grade spondylolisthesis; however, patients with LDS undergoing hemilaminectomy and one-third facetectomy may experience higher isthmus stress on the surgical side during rotation. In addition, total laminectomy changes the biomechanics in both normal lumbar models and spondylolisthesis models.


Assuntos
Fusão Vertebral , Espondilolistese , Humanos , Espondilolistese/cirurgia , Análise de Elementos Finitos , Vértebras Lombares/cirurgia , Laminectomia/métodos , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Amplitude de Movimento Articular/fisiologia , Descompressão
8.
Braz Oral Res ; 38: e010, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38597509

RESUMO

This study evaluated the stress distribution in the dentoalveolar and palatal bone structures during maxillary expansion in a 17-year-old male patient with bilateral cleft lip and palate (BCLP) using expanders with dental (HYRAX) and skeletal anchorage (MARPE). For the generation of the specific finite element models, cone-beam computed tomography was used, and the DICOM files were exported to Mimics 3-Matic (Materialise) and Patran (MSC Software) software. Three specific three-dimensional models were generated: A) HYRAX: conventional four-banded hyrax screw (9 mm); B) MARPE-DS: 3 miniscrews (1.8 mm diameter - 5.4 mm length) and four-banded dental anchorage; and C) MARPE-NoDS: 3 miniscrews without dental anchorage. Maxillary expansion was simulated by activating the expanders transversely 1 mm on the "X" axis. HYRAX resulted in higher levels of deformation predominantly in the dentoalveolar region. MARPE-DS showed stress in the dentoalveolar region and mainly in the center of the palatal region, at approximately 4,000 µÎµ. MARPE-NoDS exhibited evident stress only in the palatal region. High stress levels in the root anchoring teeth were observed for HYRAX and MARPE-DS. In contrast, MARPE-NoDS cause stress on the tooth structure. The stress distribution from the expanders used in the BLCP showed asymmetric expansive behavior. During the initial activation phase of expansion, the HYRAX and MARPE-DS models produced similarly high strain at the dentoalveolar structures and upper posterior teeth displacement. The MARPE-NoDS model showed restricted strain on the palate.


Assuntos
Fenda Labial , Fissura Palatina , Masculino , Humanos , Adolescente , Fenda Labial/diagnóstico por imagem , Fissura Palatina/diagnóstico por imagem , Análise de Elementos Finitos , Maxila/diagnóstico por imagem , Palato/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos
9.
J Biomech ; 166: 112070, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38569456

RESUMO

Cement-augmentation is a technique commonly used during posterior lumbar instrumented fusion (PLIF) to reinforce compromised osteoporotic vertebral bone, minimize the risk of loosening screws, enhance stability, and improve overall surgical outcomes. In this study, we introduce a novel segmented vertebral body regional modeling approach to investigate the effects of osteoporosis and cement-augmented lumbar fusion on disc biomechanics at spinal levels adjacent to the fused vertebrae. Using our previously validated personalized-poroelastic-osteoligamentous FE model of the spine, fusion was simulated at L4-L5, and the biomechanics of adjacent levels were studied for 30 patients (non-osteoporotic patients (N = 15), osteoporotic patients (N = 15)). PLIF models, with and without cement-augmentation, were developed and compared after an 8 h-rest period (200 N), following a 16 h-cyclic compressive loading of 500-1000 N (40 and 20 min, respectively). Movement in different directions (flexion/ extension/ lateral bending/ axial rotation) was simulated using 10Nm moment before and after cyclic loading. The material mapping algorithm was validated by comparing the results of voxel-based and parametric models. The FE cement-augmented models, subject to daily activity loading, demonstrated significant differences in disc height loss and fluid loss as compared to non-cemented models. The calculated axial stress and fiber strain values were also significantly higher for these models. This work demonstrates that although osteoporosis does not significantly alter the time-dependent characteristics of adjacent IVDs post-surgery, cement-augmentation increases the risk of adjacent segment disease (ASD) incidence. A holistic understanding of the trade-offs and long-term complex interplay between structural reinforcement modalities, including cement augmentation, and altered biomechanics warrants further investigation.


Assuntos
Osteoporose , Fusão Vertebral , Humanos , Análise de Elementos Finitos , Vértebras Lombares/cirurgia , Osteoporose/cirurgia , Cimentos Ósseos , Fusão Vertebral/efeitos adversos , Fenômenos Biomecânicos
10.
Clin Oral Investig ; 28(5): 260, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38642152

RESUMO

OBJECTIVES: The aim of this study was to evaluate the stress distributions and possible amount of movement in the maxillofacial region resulting from different maxillary advancement protocols in patients with unilateral cleft lip and palate. MATERIALS AND METHODS: A unilateral cleft lip and palate model (CLP model) with Goslon score 4 was created for finite element analysis. Three different protocols were compared: Group 1: usage of a face mask with elastics placed at a 30? angle to the occlusal plane over a conventional acrylic plate; Group 2: usage of a face mask with elastics placed at a 30? angle to the occlusal plane over miniplates placed in the infrazygomatic crest region; Group 3: usage of elastic from the menton plate placed in the mandible to the infrazygomatic plates in the maxilla. RESULTS: Dental effects were greater in the maxillary protraction protocol with a face mask over a conventional acrylic plate (Von Misses Stress Values; Group 1?=?cleft side:0.076, non-cleft side:0.077; Group 2?=?cleft side:0.004, non-cleft side: 0.003; Group 3?=?cleft side:0.0025; non-cleft side:0.0015), whereas skeletal effects were greater in maxillary protraction protocols with face mask using skeletal anchorage (Von Misses Stress Values; Group 1:0.008; Group 2:0.02; Group 3:0.0025). The maximum amount of counterclockwise rotation of the maxilla as a result of protraction was observed in traditional acrylic plate face mask protocol, and the minimum amount was observed by using elastics between infrazygomatic plates and menton plate. CONCLUSIONS: In individuals with unilateral cleft lip and palate with Goslon score 4, it was observed that the skeletally anchored face mask caused more skeletal impact and displacement than both the traditional acrylic plate face mask model and the pure skeletally supported maxillary protraction model. CLINICAL RELEVANCE: When planning maxillary protraction treatment in patients with cleft lip and palate, it should be considered that more movement in the sagittal plane might be expected on the cleft side than the non-cleft side, and miniplate and screws on the cleft side are exposed to more stress when using infrazygomatic plates as skeletal anchorage.


Assuntos
Fenda Labial , Fissura Palatina , Humanos , Fenda Labial/cirurgia , Maxila/cirurgia , Fissura Palatina/cirurgia , Análise de Elementos Finitos , Cefalometria
11.
J Mech Behav Biomed Mater ; 154: 106520, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38569421

RESUMO

The preparation of slender specimens for in-vitro tissue characterisation could potentially alter mechanical tissue properties. To investigate this factor, rectangular specimens were prepared from the wall of the porcine aorta for uniaxial tensile loading. Varying strip widths of 16 mm, 8 mm, and 4 mm were achieved by excising zero, one, and three cuts within the specimen along the loading direction, respectively. While specimens loaded along the vessel's circumferential direction acquired consistent tissue properties, the width of test specimens influenced the results of axially loaded tissue; vascular wall stiffness was reduced by approximately 40% in specimens with strips 4 mm wide. In addition, the cross-loading stretch was strongly influenced by specimen strip width, and fiber sliding contributed to the softening of slender tensile specimens, an outcome from finite element analysis of test specimens. We may, therefore, conclude that cutting orthogonal to the main direction of collagen fibers introduces mechanical trauma that weakens slender tensile specimens, compromising the determination of representative mechanical vessel wall properties.


Assuntos
Aorta , Suínos , Animais , Resistência à Tração , Análise de Elementos Finitos , Estresse Mecânico , Fenômenos Biomecânicos
12.
PLoS One ; 19(4): e0301622, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630695

RESUMO

This paper proposes a reinforced concrete (RC) boundary beam-wall system that requires less construction material and a smaller floor height compared to the conventional RC transfer girder system. The structural performance of this system subjected to axial compression was evaluated by performing a structural test on four specimens of 1/2 scale. In addition, three-dimensional nonlinear finite element analysis was also performed to verify the effectiveness of the boundary beam-wall system. Three test parameters such as the lower wall length-to-upper wall length ratio, lower wall thickness, and stirrup details of the lower wall were considered. The load-displacement curve was plotted for each specimen and its failure mode was identified. The test results showed that decrease in the lower wall length-to-upper wall length ratio significantly reduced the peak strength of the boundary beam-wall system and difference in upper and lower wall thicknesses resulted in lateral bending caused by eccentricity in the out-of-plane direction. Additionally, incorporating cross-ties and reducing stirrup spacing in the lower wall significantly improved initial stiffness and peak strength, effectively minimizing stress concentration.


Assuntos
Materiais de Construção , Compressão de Dados , Análise de Elementos Finitos , Fenômenos Físicos
13.
PLoS One ; 19(4): e0297750, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38625921

RESUMO

High-voltage dry-type bushings, serving as the crucial junctions in DC power transmission, represent equipment with the highest failure rate on the DC primary side, underscoring the critical importance of monitoring their condition. Presently, numerical simulation methods are commonly employed to assess the internal state of bushings. However, due to limitations in the efficiency of multi-physics field computations, the guidance provided by numerical simulation results in the field of power equipment condition assessment is relatively weak. This paper focuses on solving the electrical-thermal coupling in high-voltage dry-type bushings. Addressing the most widely used tetrahedral mesh in numerical computations, we propose an efficient solution method based on the concept of "smooth domains." This method involves partitioning the volume centroids of the elements into multiple smooth domains within the computational domain. Electric and thermal conduction matrix calculations occur within these smooth domains, rather than within the grid or element interiors. This approach eliminates the need for traditional element mapping and complex volume integration. To demonstrate the effectiveness of this method, we use high-voltage dry-type bushings as a case study, comparing the performance of our approach with traditional finite element algorithms. We verify the algorithm's computational efficiency and apply it to the analysis of typical temperature anomalies in bushings, further illustrating its suitability for electrical equipment condition assessment.


Assuntos
Algoritmos , Eletricidade , Simulação por Computador , Temperatura , Sistemas Computacionais , Análise de Elementos Finitos
14.
BMC Oral Health ; 24(1): 425, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582842

RESUMO

BACKGROUND: Clinical scenarios frequently present challenges when patients exhibit asymmetrical mandibular atrophy. The dilemma arises: should we adhere to the conventional All-on-4 technique, or should we contemplate placing vertically oriented implants on the side with sufficient bone mass? This study aims to employ three-dimensional finite element analysis to simulate and explore the biomechanical advantages of each approach. METHODS: A finite element model, derived from computed tomography (CT) data, was utilized to simulate the nonhomogeneous features of the mandible. Three configurations-All-on-4, All-on-5-v and All-on-5-o were studied. Vertical and oblique forces of 200 N were applied unilaterally, and vertical force of 100 N was applied anteriorly to simulate different masticatory mechanisms. The maximum von Mises stresses on the implant and framework were recorded, as well as the maximum equivalent strain in the peri-implant bone. RESULTS: The maximum stress values for all designs were located at the neck of the distal implant, and the maximum strains in the bone tissue were located around the distal implant. The All-on-5-o and All-on-5-v models exhibited reduced stresses and strains compared to All-on-4, highlighting the potential benefits of the additional implant. There were no considerable differences in stresses and strains between the All-on-5-o and All-on-5-v groups. CONCLUSIONS: With the presence of adequate bone volume on one side and severe atrophy of the contralateral bone, while the "All-on-4 concept" is a viable approach, vertical implant placement optimizes the transfer of forces between components and tissues.


Assuntos
Implantes Dentários , Humanos , Fenômenos Biomecânicos , Análise de Elementos Finitos , Estresse Mecânico , Análise do Estresse Dentário/métodos , Prótese Dentária Fixada por Implante , Mandíbula/diagnóstico por imagem , Atrofia
15.
PLoS One ; 19(4): e0298061, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38574090

RESUMO

The study presents state-of-the-art requirements verification process for the prediction of the stability of the multi-staged deep excavation in submerged soft soil retained by stell sheet pile walls structures applied at the development of elasto-plastic finite element calculation method performed from Cast3M and Plaxis FE codes. Optimization numerical calculation results are proposed for retained walls design and construction on the basis of the horizontal displacement, earth and water pressures measurements. The transformation of the geometry and stiffness of the stell sheet pile walls to the retaining walls of an equivalent bending stiffness on the one hand and regular geometric shapes allowed in this paper to overcome the difficulties of modelling these stell sheet pile walls in 2D with irregular shapes. The horizontal deflection of the wall, the vertical displacement behind the walls, and the settlement of the excavation bottom are given. They have been compared by those obtained by various authors around the world. The results of this approach are satisfactory in view of the horizontal displacement curves obtained on the stell sheet pile walls compared by the measures.


Assuntos
Solo , Solo/química , Análise de Elementos Finitos
16.
BMC Oral Health ; 24(1): 366, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38515128

RESUMO

BACKGROUND: The success of implants in the socket shield technique relies on stress experienced by root fragments within the socket. Although there is no consensus on optimal root fragment thickness, varying thicknesses and dynamic implant placement induce stress in various directions and degrees. This study aimed to assess biomechanical response and stress distribution across different root fragment thicknesses in the socket shield procedure. METHODS: This in vitro study was conducted to assess and compare the stress distribution on residual root structures of varying thicknesses positioned within the labial aspect of the maxillary incisor socket during immediate implant placement of standard dimensions. The procedure involved applying an insertional torque of 40 Ncm, and the analysis was conducted using finite element analysis software. RESULTS: Utilizing the Numerical Technique with Abaqus software for explicit dynamics, von Mises stress and principal strain were analyzed on the root structure and bone under nonlinear contact conditions during implant torque application. For Model A, a loading torque of 40 Ncm was applied vertically on the implant, along with a horizontal force of 20 N on the root structure and bone. Results indicated maximum stress of 12.68 MPa on the root structure with a thickness of 0.5 mm and 5.61 MPa on the bone, with principal strains of 6.82E-03 and 4.10E-03, respectively. In Model B, with a root structure thickness of 1.0 mm, the maximum stress increased to 19.70 MPa, while the bone stress rose to 9.51 MPa, with principal strains of 1.03E-02 and 6.09E-03. Model C, with a root structure thickness of 1.5 mm, exhibited a maximum stress of 21.58 MPa on the root and 10.12 MPa on the bone, with principal strains of 1.16E-02 and 6.10E-03. Lastly, in Model D, with a root structure thickness of 2.0 mm, the maximum stress on the root structure and bone escalated to 28.74 MPa and 11.38 MPa, respectively, with principal strains of 1.55E-02 and 8.31E-03. CONCLUSIONS: As the thickness of the shield increases (ranging from 0.5 to 2 mm) in socket shield procedures with immediate implant placement, both stress on the root fragment and bone and principal micro-strain escalate. However, employing a shield thickness within the range of 0.5 to 2 mm does not lead to any adverse stress generation on the residual root fragment. However, for enhanced safety, it is recommended to restrict the maximum diameter and extension of the root fragment to 1.5 mm when considering implant sizes and socket diameter for the socket shield technique.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Humanos , Análise de Elementos Finitos , Alvéolo Dental/cirurgia , Análise do Estresse Dentário
17.
Zhongguo Gu Shang ; 37(3): 271-7, 2024 Mar 25.
Artigo em Chinês | MEDLINE | ID: mdl-38515414

RESUMO

OBJECTIVE: To establish the finite element model of spinal canal reconstruction and internal fixation,analysis influence of spinal canal reconstruction and internal fixation on spinal stability,and verify the effectiveness and reliability of spinal canal reconstruction and internal fixation in spinal canal surgery. METHODS: A 30-year-old male healthy volunteer with a height of 172 cm and weight of 75 kg was selected and his lumbar CT data were collected to establish a finite element model of normal lumbar L3-L5,and the results were compared with in vitro solid results and published finite element analysis results to verify the validity of the model. They were divided into normal group,laminectomy group and spinal canal reconstruction group according to different treatment methods. Under the same boundary fixation and physiological load conditions,six kinds of activities were performed,including forward bending,backward extension,left bending,right bending,left rotation and right rotation,and the changes of range of motion (ROM) of L3-L4,L4-L5 segments and overall maximum ROM of L3-L5 were analyzed under the six conditions. RESULTS: The ROM displacement range of each segment of the constructed L3-L5 finite element model was consistent with the in vitro solid results and previous literature data,which confirms the validity of the model. In L3-L4,ROM of spinal canal reconstruction group was slightly increased than that of normal group during posterior extension(>5% difference),and ROM of other conditions was similar to that of normal group(<5% difference). ROM in laminectomy group was significantly increase than that in normal group and spinal canal reconstruction group under the condition of flexion,extension,left and right rotation. In L4-L5,ROM in spinal canal reconstruction group was similar to that in normal group(<5% difference),while ROM in laminectomy group was significantly higher than that in normal group and spinal canal reconstruction group(>5% difference). In the overall maximum ROM of L3-L5,spinal canal reconstruction group was only slightly higher than normal group under the condition of posterior extension(>5% difference),while laminectomy was significantly higher than normal group and spinal canal reconstruction group under the condition of anterior flexion,posterior extension,left and right rotation(>5% difference). The changes of each segment ROM and overall ROM of L3-L5 showed laminectomy group>spinal canal reconstruction group>normal group. CONCLUSION: Laminectomy could seriously affect biomechanical stability of the spine,but application of spinal canal reconstruction and internal fixation could effectively reduce ROM displacement of the responsible segment of spine and maintain its biomechanical stability.


Assuntos
Vértebras Lombares , Fusão Vertebral , Masculino , Humanos , Adulto , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos , Análise de Elementos Finitos , Reprodutibilidade dos Testes , Amplitude de Movimento Articular/fisiologia , Fenômenos Biomecânicos , Canal Medular/cirurgia
18.
Dental Press J Orthod ; 29(1): e2423195, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38451569

RESUMO

INTRODUCTION: Surgically assisted rapid palatal expansion (SARPE) has been the treatment of choice in subjects presenting skeletally mature sutures. OBJECTIVE: The purpose of this study was to analyze stress distribution and displacement of the craniofacial and dentoalveolar structures resulting from three types of palatal expanders with surgical assistance using a non-linear finite element analysis. MATERIAL AND METHODS: Three different palatal expanders were designed: Model-I (tooth-bone-borne type containing four miniscrews), Model-II (tooth-bone-borne type containing two miniscrews), and Model-III (bone-borne type containing four miniscrews). A Le Fort I osteotomy was performed, and a total of 5.0 mm palatal expansion was simulated. Nonlinear analysis (three theory) method (geometric nonlinear theory, nonlinear contact theory, and nonlinear material methods) was used to evaluate stress and displacement of several craniofacial and dentoalveolar structures. RESULTS: Regardless of the maxillary expander device type, surgically assisted rapid palatal expansion produces greater anterior maxillary expansion than posterior (ANS ranged from 2.675 mm to 3.444 mm, and PNS ranged from 0.522 mm to 1.721 mm); Model-I showed more parallel midpalatal suture opening pattern - PNS/ANS equal to 54%. In regards to ANS, Model-II (1.159 mm) and Model-III (1.000 mm) presented larger downward displacement than Model-I (0.343 mm). PNS displaced anteriorly more than ANS for all devices; Model-III presented the largest amount of forward displacement for PNS (1.147 mm) and ANS (1.064 mm). All three type of expanders showed similar dental displacement, and minimal craniofacial sutures separation. As expected, different maxillary expander designs produce different primary areas and levels of stresses (the bone-borne expander presented minimal stress at the teeth and the tooth-bone-borne expander with two miniscrews presented the highest). CONCLUSIONS: Based on this finite element method/finite element analysis, the results showed that different maxillary expander designs produce different primary areas and levels of stresses, minimal displacement of the craniofacial sutures, and different skeletal V-shape expansion.


Assuntos
Osteotomia , Técnica de Expansão Palatina , Humanos , Análise de Elementos Finitos
19.
Sensors (Basel) ; 24(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38544262

RESUMO

Optical biosensors have a significant impact on various aspects of our lives. In many applications of optical biosensors, fluidic chambers play a crucial role in facilitating controlled fluid delivery. It is essential to achieve complete liquid replacement in order to obtain accurate and reliable results. However, the configurations of fluidic chambers vary across different optical biosensors, resulting in diverse fluidic volumes and flow rates, and there are no standardized guidelines for liquid replacement. In this paper, we utilize COMSOL Multiphysics, a finite element analysis software, to investigate the optimal fluid volume required for two types of fluidic chambers in the context of the oblique-incidence reflectivity difference (OI-RD) biosensor. We found that the depth of the fluidic chamber is the most crucial factor influencing the required liquid volume, with the volume being a quadratic function of the depth. Additionally, the required fluid volume is also influenced by the positions on the substrate surface bearing samples, while the flow rate has no impact on the fluid volume.


Assuntos
Técnicas Biossensoriais , Incidência , Software , Análise de Elementos Finitos
20.
J Mol Graph Model ; 129: 108751, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38430695

RESUMO

In this paper, the finite element method is utilized to evaluate the behavior of the armchair phosphorene nanotubes under the compressive loading. The energy equations of the molecular and structural mechanics are used to obtain the elemental properties. The critical compressive forces of various armchair phosphorene nanotubes are computed with clamped-clamped and clamped-free boundary conditions. Results show that the stability of armchair phosphorene nanotubes increases with increasing nanotube aspect ratio, particularly under clamped-clamped boundary conditions. Finally, the buckling mode shapes of armchair phosphorene nanotubes under different boundary conditions are compared. Our work offers valuable insights into how these nanotubes respond to mechanical stress, helps determine elemental properties, and investigates the effects of nanotube geometry and different boundary conditions on their stability. This knowledge has broad applications in fields like nanotechnology, materials science, and nanomechanics, advancing the understanding of nanoscale materials and their potential for various practical uses.


Assuntos
Nanotubos , Análise de Elementos Finitos , Nanotubos/química , Nanotecnologia/métodos , Elasticidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...